3-3-2. Setting the 1/2 division function

By using the 1/2 division function, it is possible to halve the
number of divisions (number of interpolations) that was set
by MODE switches 6, 7, and 8 (setting switches 1, 2, and 3
for number of divisions).
The 1/2 division function setting is made using MODE switch
10 (1/2 switch).
MODE switch 10
(1/2 switch)
ON
OFF
The default setting is ON (1/2 division is not used).
Example: When the signal is split into 100 divisions in MJ500
MODE switch 10
(1/2 switch)
ON
OFF
1/2 division function
1/2 division is not used
1/2 division is used
Number of divisions
100
50
n
. MODE switch 10 (1/2 switch) does not affect the reference
point. The reference point output is determined by the A-
phase cycle that was set by mode switches 6, 7, and 8
(setting switches 1, 2, and 3 for number of divisions).
Therefore, the reference point is not synchronized with
the A/B phase when the 1/2 division function (the MODE
switch 10 is set to OFF) is used.
1/2 division is not used
A phase
B phase
Z
phase
1/2 division is used
A phase
B phase
Z
phase
The reference point output does not change even when the
1/2 division function is used.