Herunterladen Inhalt Inhalt Diese Seite drucken

Reference Point Output Modes; Level Mode - Sony MJ700 Bedienungsanleitung

Interpolator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3-4-2. Reference point output modes

OPTION switches 1 and 2 (reference point G set 1 and 2)
can be used to select one of four reference point output modes.
OPTION switch 2
OPTION switch 1
(reference point G
(reference point G
set 2)
set 1)
ON
ON
OFF
ON
ON
OFF
OFF
OFF
Level full mode
The reference point gate signal outputs the reference point
while it is active. This mode has no relation to the one-cycle
reference point. Also, the reference point is not synchronized
with the A/B phase.
One-cycle
reference
point
Reference point
gate input
Reference point
output
n
Do not use Level full mode for the input of analog reference
point gate signals. A fault can occur in the reference point
output, resulting in a malfunction.

Level mode

This mode is compatible with the standard analog reference
point gate input encoder and is enabled when the reference
point gate width is 1/4 to 3/2 wavelength of the SIN-COS
signal.
Reference point
While the reference point gate signal is active, reference point
output modes
signals are output in synchronization with the A/B phase
signals at all one-cycle reference points.
Level full mode
This mode is set in the default setting.
Level mode
Edge level mode
Edge mode
One-cycle
reference
point
Reference point
gate input
Reference point
output
(E) 15