7. Malfunction table

At a possible malfunction one can consult the table mentioned below and if you obtain on this basis no solution, we
advise to contact a diBO technician and/or a recognized DiBO representative.
Pay attention, failures only resolve at disabled cleaner!
Malfunction
Machine does not start
No water pressure
To high water pressure
Instable and to weak pressure
No addition of product
HP pump pulse
Cleaner leak
ECN-S REV 0
Cause
Electrical supply not connected
Net fuse defect
Operating switch on "0"
Rest malfunctions
Frozen apparatus
Motor protection activated
Insufficient water supply
Filter blocked
Nozzle partially blocked
Air in water supply (leaks in water
supply)
Nozzle or lance blocked or worn-out.
Filter blocked
Water supply hose clamped
Pressure regulating valve fault
Rest malfunctions
Suction line fault
Suction filter blocked
Product tank empty
Spray pressure to high (adjustment)
Leak or block in the supply line
To much air present
Rest malfunctions
Pump leak
Solution
Connect the electrical supply
Check net fuse
Put operating switch on "1"
Consult an expert
Defrost the pump/water hose or ac-
cessories
Cool down the electric motor
Repair water supply
Clean/replace the filter cartridge
Clean or replace
Put machine completely without
power! Repair leaks in supply.
Clean or replace
Clean
Lay the supply hose in free position
Consult an expert
Consult an expert
Repair suction line
Clean suction filter
Refill or replace
Lower the spray pressure
Clean/replace/repair
De-aeration of the cleaner
Consult an expert
In case of extraordinary, seriously
leakages contact the authorized
customer service