MALFUNCTION
Machine does not start
No water pressure
To high water pressure
Instable and to weak pressure
No additions of products
HP pump pulse
cleaner leak
Malfunction table
At a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a diBO technician and/or a
recognized DiBO representative.
Pay attention, failures only resolve at disabled cleaner!
CAUSE
• Electrical supply not connected
• Net fuse defect
• Main switch on "0"
• Rest malfunctions
• Frozen apparatus
• Motor protection activated
• Insufficient water supply
• Filter blocked
• Nozzle partially blocked
• Air in water supply (leaks in water
supply)
• Nozzle or lance blocked or worn-out
• Filter blocked
• Water supply hose clamped
• Pressure regulating valve fault
• Rest malfunctions
• Suction line fault
• Suction filter blocked
• Product tank empty
• Spray pressure to high (adjustment)
• Leak or block in the supply line
• To much air present
• Rest malfunctions
• Pump leak
DiBO 21
M A L F U N C T I O N TA B L E
SOLUTION
• Connect the electrical supply
• Check net fuse
• Put main switch on "1"
• Consult an expert
• Defrost the pump/water hose or
accessories
• Cool down the electric motor
• Repair water supply
• Clean/replace filter cartridge
• Clean or replace
• Put machine completely without
power! Repair leaks in supply.
• Clean or replace
• Clean
• Lay the supply hose in free position
• Consult an expert
• Consult an expert
• Repair suction line
• Clean suction filter
• Refill or replace tank
• Lower the spray pressure
• Clean/replace/repair
• De-aeration of cleaner
• Consult an expert
• In case of extraordinary, seriously
leakages contact the authorized
customer service
E N