Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Warning Notes - H-tronic AL 600plus Bedienungsanleitung

Bleibatterie-lader mit diagnosefunktion und neuester ladetechnik
Vorschau ausblenden Andere Handbücher für AL 600plus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lead battery charger with diagnostic
function
With newest charging technology
One the most modern and most intelligent
battery charging, diagnostic and test de-
vices for all 2V, 6 V and 12V lead batteries,
as well as maintenance-free gel batteries
and lead acid batteries. This battery char-
ger operates with the most modern cha-
racteristic-controlled charging technology
and thus ensures ideal charging condi-
tions and maintenance of lead batteries.
Intelligent software constantly monitors
all functions and controls the correct
charging procedure depending upon the
respective state. The battery can remain
connected for months. Overcharging is
not possible.
Five LEDs constantly indicate the opera-
ting status. This automatic charger can
remain connected to the battery during
the winter.
Special features:
• Multi-stage I/U charging characteristic
I-phase, U1-phase, U2-phase
• Electronic protective circuit protects
against reverse polarity and short-
circuit
• Automatic battery maintenance mode
(Automatic refreshing of the battery after
charging)
• Trickle charging
• Software controlled diagnosis of the
battery before beginning the charging
procedure, battery test function, defect
identification
• For 2V, 6 V and 12 V lead batteries (Acid,
gel, AGM)
• Charging current max. 0.6 A (automatic
adaptation)
• 5 LED status displays: Mains, charging,
refresh, finished, error.
Technical data: Input voltage: 220-240V/
AC, max. charging current 600 mA (12V),
300mA (2V/6V), electronic protection
against short-circuits and incorrect pola-
rity, overcharging protection, dimensions
approx. 95x70x55mm
Order No.
Please read the operating instruc-
tions before start-up!
Table of contents:
6. Brief explanation for experienced users
(Quick introduction)
7. Detailed functional description (Opera-
tion method of the device)
8. Notes

1. Intended use

The intended use of the battery charger
encompasses charging and charge re-
tention of maintenance-free gel batteries,
microflies and acid batteries, which are
suitable for the voltage and charging cur-
rent indicated in the technical data. Any
other use is not considered as intended.
Only the user/operator is responsible for
thereby resulting damage.

2. Warning notes

The device may be used for the described
purpose, if these operating instructions
are observed.
7