if necessary. It is possible that the battery
has a leakage current or that the battery is
still connected to a consumer, if the batte-
ry charger does not indicate „Finished" or
„Full" after a lengthy charging period.
Always observe the warning notes of the
battery and vehicle manufacturer before
charging.
First, connect the red terminal (+) to the
positive terminal of the battery and then
the black terminal to the negative pole (-)
of the battery. Caution! Never clamp con-
nections onto the vehicle body.
The battery charger works at an ambient
temperature of – 25 °C.... + 45 °C. Please
infer at which temperature or with which
charging parameters a lead battery must
be charged from the technical specifica-
tions of the lead battery manufacturer.
The device can reach temperatures of up
to 50°C during full load operation.
6. For experienced users (Quick intro-
duction)
Operation of the device
Connection to 230 V mains: First connect
the battery charger with the 230 V electri-
city mains (socket).
The green „Mains" LED lights up.
Set battery voltage:
Set the slide switch to 2V, 6 V and/or 12V
depending on the battery you want to
charge.
Connecting to the battery:
the red connecting terminal of the battery
charger to the positive terminal (+) of the
battery and the black terminal to the ne-
gative pole (-) of the battery. The battery
can thereby remain connected in the car/
motorcycle (see note N3).
Charging procedure
The device starts the charging procedure
automatically. The „Charging" LED indi-
cates this.
Finished
The battery charger switches the „Finis-
hed" LED on (see note N3) and goes into
the refresh mode, if all test criteria have
been fulfilled after charging and the bat-
tery has been evaluated as „Good". The
„Charging" LED extinguishes simultane-
ously and the „Refresh" LED is displayed.
The battery is therefore charged and rea-
dy for use and can be disconnected from
the battery charger.
Finally, pull the mains cable out of the so-
cket. Always pull the plug and never the
cable!
Check the acid level in non-maintenance-
free lead batteries. Fill with distilled water,
if the acid level is too low. Observe the
battery manufacturer's operating instruc-
tions.
10. Detailed description of the char-
ging procedure
The „Mains" LED lights up after connec-
ting to the electrical mains (230V/50Hz).
The device goes into the check mode af-
ter setting of the battery type by means
of the slide switch and connecting a 2V,
6 V or 12 V lead battery (Acid, gel, AGM,
EXIDE gel battery). The „Error" LED as
well as the „Charging" LED flashes, if the
Connect
voltage of a correctly connected battery
is higher than 14.3 V (for a 12 V battery)
or more than 7.15 V in the case of a 6 V
battery or more than 2.4 V in the case of
2 V battery.
The device switches to the charging
mode, if the voltage is in the range of
9