The test must be conducted by a technician
The gas hose and gas cylinder must be connected.
– Turn off all consumers.
– Open stop valves and, if present, the gas remote switch.
– Press in the triggering element of the crash sensor (9) sufficiently
far that the yellow reset button (7) comes out so that the crash sen-
sor is in the "not ready for operation" position (figure 2b).
– Remove the screw cap (10) from the test connection and connect
the test pump with test hose to the test connection.
Figure 3: MonoControl CS
– Check for leaks (e.g in Germany in accordance with G 607).