Electrical Connection; Cable Routing - Balluff BTL6-U101-M.... -B-S4 series Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL6-U101-M_ _ _ _ -A/B/Y/Z-S4
Transducer – Rod Style
4
Installation and connection (continued)
Magnet
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, transducer installed with supporting rod
4.4

Electrical connection

Pin
1
2
3
4
C/Q (communication line)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Tab. 4-2:
Pin assignment of S4 connector
4
Fig. 4-9:
Pin assignment of S4 connector (view from above on
transducer)
10
english
BTL6-U...-S4
L+ (18
30 V)
...
Not used
1)
L– (GND)
3
2
1
4.5

Cable routing

Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Magnetic fields
The position measuring system is a magnetostrictive
system.
It is important to maintain adequate distance between the
transducer/holding cylinder and strong, external magnetic
fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Cable length
Max. cable length 20 m. Longer cables may be used if
their construction, shielding and routing prevent noise
interference.