Technical data

7.1
Accuracy
The specifications are typical values for the BTL6-U... at
24 V DC, and room temperature, with a nominal length of
500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R, or BTL-P-1014-2R
magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
Repeat accuracy
Sampling rate
(dependent on the nominal
length)
Non-linearity at
Temperature coefficient
1)
Max. detectable velocity
7.2

Ambient conditions

Operating temperature
Storage temperature
Humidity
Shock rating
Continuous shock
per EN 60068-2-27
3)
Vibration
per EN 60068-2-6
3)
Degree of protection per
IEC 60529
(when attached)
7.3

Supply voltage (external)

Voltage, stabilized
4)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
20
english
5 µm
≤ 30 µm
≤ 1 kHz
±50 µm
≤ 30 ppm/K
10 m/s
2)
–40°C...+85°C
−40°C...+100°C
< 90%, non-condensing
100 g/6 ms
50 g/2 ms
12 g, 10...2000 Hz
IP67
18...30 V DC
≤ 0.5 V
PP
≤ 150 mA
≤ 3 A
Up to 36 V
(supply to GND)
Up to 36 V
500 V DC
7.4

IO-Link interface

Transfer protocol
Transfer rate
Cycle time min.
Master-device process data
Device-master process data
PD cycle on 1.0 master min.
PD cycle on 1.1 master min.
Output value
Data format
Error value
7.5

Dimensions, weights

Rod diameter
Nominal length
Weight (depends on length)
Housing material
Rod material
Rod wall thickness
Housing mounting via threads M18×1.5 or 3/4"-16UNF
Tightening torque
Nominal length 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
3)
Individual specifications as per Balluff factory standard, resonances
excluded
4)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
IO-Link 1.1
COM3 (230.4 kBaud)
1 ms
0 bytes
4 bytes
4 ms
1 ms
Position in µm
32-bit signed
0×7FFFFFFC
10.2 mm
25...4572 mm
Approx. 2 kg/m
Aluminum
Stainless steel
2 mm
≤ 100 Nm