Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature; Io Link Variant Config - Balluff BTL6-U101-M.... -B-S4 series Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL6-U101-M_ _ _ _ -A/B/Y/Z-S4
Transducer – Rod Style
6
IO-Link interface (continued)
6.6.7

Temperature

The following temperature values are output by the
transducer as signed 8-bit values with the unit °C:
Current temperature (subindex 1)
Maximum temperature since power-up (subindex 2)
Minimum temperature since power-up (subindex 3)
Maximum temperature over the entire lifetime
(subindex 4)
Minimum temperature over the entire lifetime
(subindex 5)
The temperature sensor detects the
temperature within the transducer. This is
always higher than the ambient temperature.
6.6.8

IO Link Variant config

This parameter should only be used for initial
parameterization of another device variant.
Using this parameter, the IO-Link variant or device
configuration can be adjusted (see section Process data
(PD) on page 14). Access takes place via subindex 0
with an 8-bit unsigned integer value.
The following device variants can be selected:
Value Product name
Device ID
0x00
BTL6-U100-...
0x030200
0x01
BTL6-U101-...
0x030201
2)
0x02
BTL6-U102-...
0x030202
0x03
BTL6-U103-...
0x030203
0x04
BTL6-U104-...
0x030204
0x05
BTL6-U105-...
0x030205
0x06
BTL6-U106-...
0x030206
0x07
BTL6-U107-...
0x030207
ABYZ stands for the respective housing style
1)
Standard variant, see Tab. 6-1
2)
Tab. 6-8:
Parameters of the different
BTL6-U10_-... IO-Link device variants
This parameter changes the device's basic
communication settings. Changing parameters
automatically triggers a device restart; the
corresponding error messages in the superior
system must be accepted.
The parameter is not reset to factory settings
via the Factory Reset function (see section 6.5).
www.balluff.com
Product ID
Transfer rate
1)
BTL6ABYZIOL000
COM3
BTL6ABYZIOL001
COM3
BTL6ABYZIOL002
COM3
BTL6ABYZIOL003
COM3
BTL6ABYZIOL004
COM2
BTL6ABYZIOL005
COM2
BTL6ABYZIOL006
COM2
BTL6ABYZIOL007
COM2
Due to the special functionality, the parameter is not listed
in the IO device description (IODD) and is not intended for
data storage. For operation in a special IO-Link variant,
Compatibility Mode is supported between the individual
variants (see Basic knowledge about IO-Link on
page 12).
Amount of process
Min. cycle
data device – master
time
0x83 (4 bytes)
0x0A (1 ms)
0x87 (8 bytes)
0x0A (1 ms)
0x8F (16 bytes)
0x0F (1.5 ms)
0x9F (32 bytes)
0x14 (2 ms)
0x83 (4 bytes)
0x28 (4 ms)
0x87 (8 bytes)
0x3C (6 ms)
0x8F (16 bytes)
0x47 (9.2 ms)
0x9F (32 bytes)
0x60 (14.4 ms)
english
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis