the terminal box of the motor must be pressed
(fig. 13).
G
● On three-phase versions, simply return the button
B
of the pressure switch to the ON position. (fig.
12).
● Single-phase versions are fitted with a pressure
switch equipped with a delayed closing air
discharge valve which facilitates start-up of the
motor. Therefore venting of air from this valve for
a few seconds with the receiver empty is normal.
● All the compressors are fitted with a safety valve
2. LAYOUT
1. Intake air filter
2. Pressure vessel
3. Wheel
4. Supporting foot
5. Quick-lock coupling (regulated compressed air)
6. Pressure gauge (for reading the preset tank
pressure)
7. Pressure regulator
8. ON/OFF switch
9. Transportation handle
10. Safety valve
11. Receiver condensation drainage tap
12. Pressure gauge (for reading the tank pressure)
13. Quick-lock coupling (unregulated compressed
air)
14. Oil dipstick (oil filler opening)
15. Oil drainage screw
16. Axle
17. Clip
18. Bolt
19. Nut
20. Washer
3. SCOPE OF USE
The compressor is designed for generating com-
pressed air for tools operated by compressed air.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the ma-
chine is used in commercial, trade or industrial busi-
nesses or for equivalent purposes.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
that is tripped in the case of malfunctioning of
the pressure switch in order to assure machine
safety.
● When fitting a tool, the flow of air in output must
be switched off.
● When using compressed air, you must know and
comply with the safety precautions to be adopted
for each type of application (inflation, pneumatic
tools, painting, washing with water-based
detergents only, etc.).
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of any
kind caused as a result of this.
4. POINTS TO NOTE WHEN SET-
TING UP THE COMPRESSOR
● Examine the machine for signs of transit dam-
age. Report any damage immediately to the
company which delivered the compressor.
● The compressor should be set up near the work-
ing consumer.
● Avoid long air lines and long supply lines (exten-
sions).
● Make sure the intake air is dry and dust-free.
● Do not set up the compressor in damp or wet
rooms.
● The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
● The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with sprayed
water.
● The oil level in the compressor pump has to
be checked before putting the equipment into
operation.