Cleaning, maintenance, before a long shutdown period
Filter cleaning
Clean filters in accordance with the actual operating
conditions and times.
Lift the front panel and pull the air filters downward.
Standard filter cleaning
Vacuum clean or rinse under running water after using a month.
Put the filters back in the correct position.
Cleaning of photocatalytic filters
• Clean photocatalytic filters by washing them under running water
(without any detergent) and regenerate them by exposing them
to sunlight for 6 hours.
• Replace active carbon and photocatalytic filters every two years.
• Replace electrostatic filters every three months.
Washing the front panel
Lift the front panel up to the top of the unit.
Then separate the front panel from the unit.
Rinse the panel under running water, and dry it completely in a
shaded area.
Air conditioner maintenance
Cleaning unit coil:
It is recommended to clean the coil at least at the beginning of each
cooling season or when necessary; turn the unit off first.
• Use a vacuum cleaner or a long-bristle brush to avoid damage to
the coil fins.
• Watch the fin edges to avoid injury.
• Damage to the fins may cause reduced coil efficiency resulting in
increased running costs. Use of flames, liquid or aerosol solvents
must be avoided. Use of these substances will cause serious
damage to the panels and electric parts.

Before a long shutdown period

Clean filters and reposition them in the unit.
Keep the unit in operation for half a day in ventilation (fan only)
mode in order to dry all the internal parts.
Switch the electric mains supply off.
Take the batteries out of the controller.
Clean indoor and outdoor units.