Herunterladen Inhalt Inhalt Diese Seite drucken

Ingeteam INGECON SUN 10TL Handbuch Für Montage Und Betrieb Seite 127

Vorschau ausblenden Andere Handbücher für INGECON SUN 10TL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
Maintenance
If you acquire the fuses from third parties they must meet the following specifications:
Maximum string power (Impp)
Gauge
15 A
12 A
10 A
8 A
6 A
To replace the fuses, proceed as indicated below:
1.
Remove voltage as explained in Section "13. Shutting down the unit".
2.
Wait 5 minutes for the voltage to discharge.
3.
Open the unit.
4.
Check that there is no voltage on the unit.
5.
Remove the polycarbonate guard.
6.
Remove the fuse using the extractor.
ABI2011IQM01_B - Installation and Operation Manual
DC Fuses
4 ~ 4.5 A
4.5 ~ 6 A
6 ~7.5 A
7.5 ~ 9 A
9 ~ 11 A
Manufacturer
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Fuse gauge
6 A
8 A
10 A
12 A
15 A
Manufacturer reference
PV-15A10F
491629
50 215 28.15
PV-12A10F
491625
50 215 28.12
PV-10A10F
491620
50 215 28.10
PV-8A10F
491615
50 215 28.8
PV-6A10F
491610
Ingeteam
DE
EN
ES
FR
IT
PT
127