Product Description

Bitron C is a powerful UVC clarifier for controlling algae and harmful bacteria.
• The bypass technology ensures optimum irradiation of the dirty water even at high flow through rates.
• The cleaning rotor continuously removes soiling from the quartz glass.
• Individual regulation of the water flow rate allows optimum adjustment to the connected filter pump.
• Suitable for fitting to OASE filter systems ProfiClear, BioSmart, BioTec and BioTec Screenmatic.
• Integrated magnets protect the filter technology from calcium deposits.
• Visual function check of the UVC lamp.
• Quick release system for easy lamp replacement.

Intended use

Bitron C, referred to as "unit", may only be used as specified in the following:
• For cleaning garden ponds, swimming ponds, pools and aquariums.
• Operate in accordance with instructions.
The following restrictions apply to the unit:
• Never operate the UVC lamp outside the casing or use it for any other purposes. The UVC radiation is harmful to the
eyes and skin even in small doses.
• Never use the unit to convey fluids other than water.
• Never run the unit without water.
• Do not use for commercial or industrial purposes.
• Not to be used for sterilising drinking water or other fluids.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Installation and connection

Operation with pool water or salt water
• For operation with pool water or salt water, the following limits must be adhered to:
Type
pH value
Free chlorine
Bound chlorine
Chloride content
Salt content
Water temperature
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.
Distances to be adhered to
 B
• Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
• Garden pond or aquarium:
– Install the unit at least 2 m away from the water.
• Allow sufficient space for carrying out maintenance work.
– Ensure that there is space of at least double the width of the casing for removing the unit head.
Solo operation
 C
• Only install the unit in the permitted positions to ensure fault-free operation.
• Take the required distances into consideration.
• Use suitable fastening material for the type of ground. Ensure that the fastening means securely hold the unit. Take
the weight of the unit into consideration.
• Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level.
This allows the water supply to be shut off for maintenance work.
Pool water
7.2 ... 7.6
0.3 ... 0.6mg/l
< 0.2 mg/l
< 200 mg/l
+4 ... +30°C
- EN -
Salt water
7.5 ... 8.5
< 0.3mg/l
< 3.5 %
+4 ... +25°C