Appliance shutdown

Scanning the error menu
The error menu only appears if the appliance has a fault.
1
2
1 Electronic assembly symbol
f Replace the electronic assembly.
f
2 Safety circuit symbol
f Check the AE 3 connection; replace the AE 3 if required.
f
3 Outlet sensor symbol
f Check the outlet sensor connection; replace the outlet sensor
f
if required.
4 Motorised valve symbol
f Check the motorised valve connection; replace the motorised
f
valve if required.
Scanning the control menu
1
2
1 Inlet temperature symbol,
shows the current inlet temperature (shows 1.0 °C if the sen-
sor is faulty).
2 Outlet temperature symbol,
shows the current outlet temperature (shows 65.0 °C if the
sensor is faulty).
3 Flow rate symbol,
shows the current flow rate.
4 Power consumption symbol,
shows the current power consumption.
Scanning the appliance data menu
1
2
1 Service code symbol,
information for service engineers.
2 Symbol for power supply runtime,
accumulated runtime in days.
3 Heating hours symbol,
accumulated heating time in hours.
4 Maximum output symbol
The value shown may diverge by several kW from the rated
output if mains voltages other than 400 V prevail.
38
|DHE SLi
3
4
3
4
3
4
Setting the anti-scalding protection
Use this anti-scalding protection for use with a shower or in plac-
es such as nurseries and hospitals. The temperature set here is
also the upper limit for the childproofing temperature setting (see
chapter "Appliance settings").
Setting
Description
21 - 60 °C
Setting range
43
For example in nurseries, hospitals, etc.
55
Max. for shower operation
60
Factory setting
No jumper
Limited to 43 °C
CAUTION Burns
If the water supplied to the appliance is preheated, the
internal anti-scalding protection and the temperature
limit that is adjustable by the user may be exceeded.
In such cases, limit the temperature with an upstream
central thermostatic valve (ZTA 3/4).
Note
The anti-scalding protection setting can only be modified
by a qualified contractor. Simultaneously pressing the M
+ i key will not change the setting.
13. Appliance shutdown
f Isolate all poles of the appliance from the power supply.
f
f Drain the appliance (see chapter "Maintenance").