INSTALLATIoN
Safety
INSTALLATIoN
7.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
Material losses
!
Observe the maximum inlet temperature. Higher tem-
peratures may damage the appliance. You can limit
the maximum inlet temperature by installing a central
thermostatic valve (see chapter "Appliance description /
Accessories").
WARNING Electrocution
This appliance contains capacitors which are discharged
when disconnected from the power supply. The capacitor
discharge voltage may briefly reach > 60 V DC.
7.2
Shower operation
CAUTION Burns
f When supplying a shower, set the internal an-
f
ti-scalding protection to 55 °C or less; see chapter
"Customer service / Setting the anti-scalding pro-
tection".
CAUTION Burns
If the water supplied to the appliance is preheated,
please note the following points:
- The internally adjustable anti-scalding protection
and the temperature limit that is adjustable by the
user may be exceeded.
- The dynamic anti-scalding protection between the
appliance and the wireless remote control may not
be effective.
f In both cases, limit the temperature with an up-
f
stream central thermostatic valve (ZTA 3/4).
7.3
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
- The IP 25 (hoseproof) rating can only be ensured with a cor-
rectly fitted cable grommet.
30
|DHE SLi
- The specific electrical resistivity of the water must not fall
below that stated on the type plate. In a linked water net-
work, observe the lowest electrical water resistance (see
chapter "Specification / Application areas"). Your water sup-
ply utility will advise you of the specific electrical water resis-
tivity or conductivity.
8.
Appliance description
8.1
Standard delivery
The following are delivered with the appliance:
- Mounting bracket
- Installation template
- 2 twin connectors
- Cross-piece
- Tee
- Flat gaskets
- Strainer
- Plastic profile washer
- Plastic connection pieces/installation aid
- Cover and back panel guides
8.2
Accessories
Remote controls
- FFB 1 SL - Wireless remote control
Control from two locations
- FFB 2 SL - Wireless remote control
Wireless remote control unit as extension of the FFB 1 SL
- FB 1 SL - Hardwired remote control
Control only with remote control unit, suitable for self-sup-
porting installation
Taps
- MEKD - kitchen pressure tap
- MEBD - bath pressure tap
Plugs G ½ A
The plugs are required if you use any taps other than the pressure
taps for finished walls recommended in the accessories.
Installation set for finished walls
- Solder fitting - copper pipe for solder connection Ø 12 mm
- Compression fitting - copper pipe
- Compression fitting - plastic pipe (suitable for Viega: San-
fix-Plus or Sanfix-Fosta)
Universal mounting frame
Mounting frame with electrical connections.
Pipe assembly for undersink appliances
This assembly for undersink installation is required if you need to
have the water connections (G ⅜ A) above the appliance.
www.stiebel-eltron.com