Herunterladen Inhalt Inhalt Diese Seite drucken

WAGNER NESPRAY PLUS Originalbetriebsanleitung Seite 41

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NESPRAY PLUS
Avoid sharp bends and folds: the smallest bending radius
is about 20 cm.
Do not drive over the high-pressure hose. Protect against
sharp objects and edges.
Never pull on the high-pressure hose to move the device.
Do not twist the high-pressure hose.
Do not put the high-pressure hose into solvents. Use only
a wet cloth to wipe down the outside of the hose.
Lay the high-pressure hose in such a way as to ensure that
it cannot be tripped over.
Only use WAGNER original-high-pressure
hoses in order to ensure functionality, safety
and durability.
1.11
PROTECTIVE EARTHING OF THE HEATING HOSE
In case of defect (of the heating conductor), protection against
an electric shock is secured by the protective earthing of the
heating hose. This earthing is implemented by the electric
supply to a shock proof socket
Be sure that the grounding of the shock proof
socket, to which the heating-hose will be con-
nected, is installed as prescribed and func-
tioning.
1.12
ELECTROSTATIC CHARGING (FORMATION OF
SPARKS OR FLAMES)
Electrostatic charging of the unit may occur
during spraying due to the flow speed of
the coating material. These can cause sparks
and flames upon discharge. The unit must
therefore always be earthed via the electrical
system. The unit must be connected to an
appropriately-grounded safety outlet.
Electrostatic charging of spray guns and the high-pressure
hose is discharged through the high-pressure hose. For this
reason the electric resistance between the connections of the
high-pressure hose must be equal to or lower than 1 MΩ.
1.13
USE OF UNITS ON BUILDING SITES AND
WORKSHOPS
The unit may only be connected to the mains network via a
special feeding point with a residual-current device with INF
≤ 30 mA.
Wagner's accessories program also includes
a mobile operator protection device for the
electronic supply, which can also be used
with other electronical equipment.
1.14
VENTILATION WHEN SPRAYING IN ROOMS
Adequate ventilation to ensure removal of the solvent vapors
has to be ensured.
1.15
SUCTION INSTALLATIONS
The are to be provided by the unit user in accordance with the
corresponding local regulations.
1.16
PERSONAL PROTECTION WHILE HOT SPRAYING
-> Wear protective gloves.
Attention: The high-pressure hose and the
hose whip are heated, too!
Use of a plastic coated spray gun is recom-
mended.
1.17
EARTHING OF THE OBJECT
The object to be coated must be earthed.
(Building walls are usually earthed naturally)
1.18
CLEANING THE UNIT WITH SOLVENTS
When cleaning the unit with solvents, the
heating of the heating hose has to be switched
off, because an explosive gas/air-mixture can
emerge in the hose. The solvent should never
be sprayed or pumped back into a container
with a small opening (bunghole). An explo-
sive gas/air mixture can arise. The container
must be earthed.
1.19
CLEANING THE UNIT
Danger of short-circuits caused by water in-
gression!
Never spray down the unit with high-pres-
sure or high-pressure steam cleaners.
1.20
SOCKET FOR HOSE DRUM AT THE UNIT
Humid cleaning in the area of the socket may only be car-
ried out in a closed state (with protective cap or connected
hose drum cable). When cleaning sockets and multifunction
switches unplug the power plug.
1.21
WORK OR REPAIRS AT THE ELECTRICAL
EQUIPMENT
These may only be carried out by a skilled electrician. No li-
ability is assumed for incorrect installation.
GB