8 Technical Specifications
Pellux 100 boiler
Technical parameters
Boiler class
Rated power
Net weight
Water capacity
Power supply
Boiler efficiency
Boiler temperature range
Operating temp max
Return temp min (at the boiler inlet)
Flue gas temp
Noise level
Outlet
Pressure max
EN
Flue gas draught required
Length of combustion chamber
Degree of protection
Chimney diameter
Chimney height (recommended)
Power consumption in standby mode
Power consumption at nominal power
Power consumption at min power
Flue gas mass flow – at rated power
Flue gas mass flow – at min power
Pressure drop at the boiler – Δ10 °C
Pressure drop at the boiler – Δ20 °C
(1) at Q = 0,8 m3/h, (2) at Q = 1,3 m3/h, (3) at Q = 1,6 m3/h, (4) at Q = 2,5 m3/h
PBMAX burners
Technical parameters
Burner capacity
Fuel
Power supply
Electric power
Electric power at start-up
Degree of protection
Net weight
18
Chapter 8 |
Technical Specifications
PELLUX 100/20
Unit
(K-PAA 20)
-
kW
kg
l
V
%
°C
°C
°C
°C
dB
mm
MPa (bar)
Pa
mm
-
mm
m
W
W
W
kg/h
kg/h
mbar
mbar
Unit
PBMAX 20.1
kW
6 ÷ 20 kW
Ø 6 ÷ 10 / max. length 30
mm
V
W
W
-
14,5
kg
PELLUX 100/30
(K-PAA 30)
5
20
30
202
245
60
70
1/N/PE 230 V, 50 Hz
90 - 92
60-80
85
45
80 ÷ 150
48 dB
ø127
0.25 (2.5)
18 ÷ 20
20 ÷ 40
320 mm
IP 21
130-160
7 m
8 m
13 W
43 W
54 W
20 W
26 W
42 kg/h
64 kg/h
18 kg/h
28 kg/h
2
mbar
6
(1)
(2)
6
mbar
17
(3)
(4)
PBMAX 30
9 ÷ 30 kW
1/N/PE 230 V, 50 Hz
40
650
IP 21
17
PELLUX 100/20 TOUCH
PELLUX 100/30 TOUCH
5
mbar
mbar