GB Technical specifications
SE
Hot water capacity
Charge power
NL number*
(kW)
8,5
10
13
15
*
Tested with heat pump
NL number:
According to DIN 4753
T50:
Heating time from 10 to 50 °C.
Vmax: Maximum hot water volume at 50 °C in the
water heater. 12 l/min gives 550 litres 40 °C
mixed water. Incoming cold water 10 °C.
Technical specifications
Corrosion protection
Volume, hot water heater
Volume, double jacket
Net weight
Heat content at 50 °C
Equivalent amount of hot water (40°C)*
Max. immersion heater length
Part.no
*
With an incoming temperature of 10 °C and hot water usage of 12 l/min.
10
T50 (minutes)*
4
205
4,25
190
4,5
150
4,75
95
Enclosed kit
Insulation plug
All cover discs
Installation and Maintenance Instructions
Accessories
LSA 10
Direct-current anode
Part no 089 308
Immersion heater
IU 31 - IU 311
K11 Junction box
Part no 018 893
litres
litres
kg
kWh
litres
mm
VPA 450/300
CU
copper
enamel
450
450
285
285
285
300
25
25
550
550
750
750
K10
088 660
088 670
K11
E