Controller Statuses

STATUS
The burner is deactivated. Lack of consent for
TURNED OFF
its operation.
Cleaning of the burner with a strong air
CLEANING
stream and grate ejection.
Lighting up of fuel. Administration of the initial fuel
FIRING UP
dose and launching the igniter and the blower.
Once the flame is detected in the firing up phase,
INCANDESCING
the blower speed increases to incandesce the fur-
nace.
The burner operates with modulated power
MODULATION
(power range).
Extinguishing of the furnace. Blower oper-
BURNING OFF
ates until the flame disappears.
The burner is deactivated, but there is agree-
STOP
ment for its operation. The required boiler
temperature has been reached.

Main Menu Operation

After selecting the MENU button on the boiler controller
main screen, you get access to the following functions:
Boiler
Burner
Heating
DHW
Solar heating (requires extension module)
Buffer
Alarm history
Menu level (PIN)
Software info
Boiler
Current temperature
Return
Circulating
pump
The BOILER submenu presents the current set boiler
temperature, preset programme and operating mode.
After pressing the SETTINGS button, you enter the fol-
lowing boiler settings:
Set temperature [�C]- temperature you want to
get on the boiler; modulation between 60-80 ºC.
Histeresis on [�C] - temperature, to which the
temperature set point must drop, so that the boil-
er can start working again; modulation between
0-20 ºC.
Histeresis off [�C] - temperature, of which the
temperature set point must be exceeded, so that
the boiler will stop working; modulation between
0-20 ºC.
PELLUX 100/20 TOUCH
PELLUX 100/30 TOUCH
DESCRIPTION
Operating
mode
Schedule
Settings
Burner
Return
The BURNER submenu presents the current operating
status of the burner, the brightness of the photocell and
the number of revolutions per minute. After pressing
the SETTINGS button, you enter the following burner
settings:
Air correction [%] - allows correction of the preset
amount of air supplied to the combustion process.
Min power [%] - bottom limitation of the burner
power modulation range.
Max power [%] - upper limitation of the burner
power modulation range.
Heating
CH temp
Set manually
Return
Current CH
temp.
Circulating
pump
Mixing valve
The HEATING submenu presents the current central
heating temperature set point, preset programme and
operating mode. After pressing the SETTINGS but-
ton, you enter the following CH settings:
Comfort temperature [�C] - room temperature
set point within the comfort range, in the Time
mode or in the Comfort mode.
Economical temperature [�C] - room tempera-
ture set point within the economic range, in the
Time mode or in the Economic mode .
Histeresis [�C] - Accuracy of maintaining the
room temperature set point. It can also affect the
boiler activation frequency. The burner switches
ON less frequently at higher hysteresis.
Room sensor calib. [�C] - enables correction in
case of incorrect indication, basing on the refer-
ence thermometer.
Work mode - selected operating mode of the cir-
cuit.
HC temp. set manually [�C] - system tempera-
ture set point, when weather control is not used.
Section 5 |
First Start-Up & Operation of the Boiler
Status
Photocell
RPM
Settings
Current temp.
on the boiler
Operating
mode
Schedule
Settings
EN
11