REPLACEMENT
If there is any sign of wear or if the product or parts thereof are damaged, it must be
replaced. When the product has been replaced, observe the steps ASSEMBLY, LEAK
TESTING, and START-UP. To ensure that the installation works faultlessly under normal
operating conditions, it is recommended to replace system parts subject to wear or ageing,
e.g. pressure regulators, hose assemblies, shut-off devices, as required:
• Recommendation: replacement times 5 years.
In case of continuous gas escaping via the pressure relief valve PRV via the breather the
pressure regulator must be replaced with a new pressure regulator.
In case of gas smells, leaks, gas escaping via the PRV or faults in the consumption
equipment, SHUT DOWN THE SYSTEM immediately. Contact a specialised company.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.
RESTORATION
If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.
SHUT-DOWN
Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Close all free connections in the feed lines of the LPG system tightly with a
suitable cap to prevent gas from flowing out.
Close the gas cylinder valve(s) for storage and transport.
The protective cap serves as additional protection against the escape of gas in the event of
leaks.
Mount the protective cap to secure the gas cylinder valve(s) during transport.
DISPOSAL
To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.
CERTIFICATE
Our management system is certified according to ISO 9001, ISO 14001 and
ISO 50001, see:
www.gok-online.de/de/zertifikate/qualitaets-und-umweltmanagementsystem.
part no. 02 018 51c
Caramatic Basic Two
11 / 12