The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
The product can be damaged if the gas cylinder is moved!
Entrained liquid phase can cause the pressure to increase in the LPG system and damage
the product or the LPG system.
Do not move the gas cylinder while the system is in operation.
Do not operate while driving!
If LPG is withdrawn too quickly or is continuously withdrawn from the cylinder on
the operating side, the temperature of the gas falls and, as a result, the cylinder pressure
drops below the required inlet pressure of the regulator. LPG is then also withdrawn from the
spare cylinder.
Proper operation of the system is no longer guaranteed.
The LPG cylinders on both sides may be emptied simultaneously or also at different
rates.

TROUBLESHOOTING

Fault cause
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
No gas flow.
Abnormal flame pattern of
non-adjustable pressure
regulator
Pressure gauge indicates
incorrect values or is not
working at all.
10 / 12
If the gas system is only being operated with one gas
cylinder, you should use the central regulator
To do this, turn the rotary knob
to the "Reserve" position, close the gas cylinder valve and release
the connection
of the changeover regulator
Now, hang up and secure the changeover regulator not being
used
onto the regulator bracket to protect it from damage. The
non-return gas valve prevents gas from escaping from the free
connection
of the changeover regulator not being used
Action
 Close the gas supply.
 Do not use any electric switches.
 Do not use a phone in the building.
 Ventilate rooms well.
 Shut down the LPG system.
 Contact a specialised company.
 Open the gas cylinder valve or the shut-off fittings.
Compare the nominal outlet pressure with the nominal
connection pressure:
 if they do not correspond, replace the pressure regulator
or the gas appliance
 pressure regulator is defective, replace
 check the gas filter
Pressure gauge is defective.
 Close the gas feed: replace only when the
LPG system is completely de-pressurised.
Perform LEAK TESTING activities.
Caramatic Basic Two
.
on the changeover regulator
.
part no. 02 018 51c
.