Herunterladen Inhalt Inhalt Diese Seite drucken

During Use; Adjusting The Flow Rate; Warnings And Alarms; After Use - Dräger X-plore 8000 Gebrauchsanweisung

Gebläsefiltergerät
Vorschau ausblenden Andere Handbücher für X-plore 8000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

b. Put on belt and close buckle. The device is located on
the back of the user.
c. Tighten belt and fasten protruding ends with clips on
ends of the belt.
8. Connecting the facepiece:
a. Connect the plug-in connector of the breathing hose to
the fan unit.
b. Connect the other end of the breathing hose to the
facepiece.
9. Switch on the fan unit by pushing the
control panel for approx. 2 seconds.
 The device performs a self-test. If the device does not
work properly or warning devices are triggered,
eliminate the fault (see chapter 4 Troubleshooting).
10. Don the facepiece (see Instructions for Use of the
corresponding facepiece).
11. Adjust he volume flow as desired using the
buttons.
3.3

During use

WARNING
Health hazard
► Leave the danger zone immediately in case of:
– Decreasing or interrupted air supply (e.g. after fan
failure). In the hood/helmet/protective visor facepiece
type, carbon dioxide can quickly build up or lack of
oxygen may occur. Noxious ambient air may also
penetrate the hood.
– Odour or taste developing in the facepiece (filter
break). The residual capacity of the gas filter or the gas
filter components of the combination filter are
exhausted.
– Drowsiness, dizziness, or other complaints
– Damage to the equipment
– Displayed alarms
Breathing hoses or other components involve the risk of
getting caught. This may damage the device and interrupt
the air supply!
Handle the device with care.
Breathing in during heavy work while wearing the
hood/helmet/protective visor facepiece type may result in
negative pressure and the penetration of unfiltered
ambient air!
Increase the flow rate to prevent this from happening.

3.3.1 Adjusting the flow rate

If necessary (e.g. during increased physical exertion), the flow
rate must be adjusted during operation using the
buttons.

3.3.2 Warnings and alarms

If a warning appears, leave the working area promptly in view
of the potentially hazardous situation.
Lower the flow rate to increase the period of service if a
warning appears. (Only possible if the lowest level has not
already been chosen.) By lowering the flow rate, you can, for
example, extend the battery runtime.
If an alarm is triggered, leave the working area immediately
without any delay.
Check the function of the device after a warning or alarm has
been triggered.
Instructions for use
|
Dräger X-plore® 8000
3.4
Do the following:
1. Leave the hazardous area.
2. Remove the facepiece (see Instructions for Use of the
corresponding facepiece).
3. Switch off the fan unit by pushing the
control panel for approx. 2 seconds.
4. Open the carrying system belt and take off the device.
5. Clean and disinfect the device (see chapter 5.2 Cleaning
button on the
and disinfecting).
4
4.1
and
Fault
A segment of the
battery status indi-
cator is flashing
yellow.
A segment of the
particle filter resid-
ual capacity indica-
tor is flashing
yellow.
A segment of the
flow rate indicator
is flashing yellow.
4.2

4.2.1 Fan unit

Fault
A segment of the
battery status indi-
cator is flashing
red.
A segment of the
particle filter resid-
ual capacity indica-
and
tor is flashing red.
A segment of the
flow rate indicator
is flashing red.
One segment at a
time is flashing red.

After use

Troubleshooting

Warnings

Cause
The residual run-
time of the
rechargeable bat-
tery is low
(< 30 minutes).
The particle filter
residual capacity is
low (< 20 %).
Malfunction during
switch-on (e.g.
caused by missing
hose or filter).

Alarms

Cause
The residual run-
time of the
rechargeable bat-
tery is almost
exhausted
(< 10 minutes)
The particle filter
residual capacity is
almost exhausted
(< 10 %)
Faulty breathing air
supply during oper-
ation (e.g. caused
by missing hose,
filter or kinked
hose).
General system
error
|
en
Troubleshooting
button on the
Remedy
Recharge the bat-
tery soon or
replace with fully
charged battery.
Change particle or
combination filter
soon.
Re-check the
device function
and prepare for
use.
Remedy
Recharge the bat-
tery or replace with
fully charged bat-
tery.
Change particle or
combination filter.
Re-check the
device function
and prepare for
use.
Device must be
checked by Dräger
Service.
21

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis