OPTIONAL FORCE SETTING
The factory-set forces (value 3) are designed to enable a smooth operation of standard doors (which are intended for use
with this drive). The forces exerted in the factory setting should fundamentally be sufficient to completely open and close
the door to be operated. In the factory default setting, the drive complies with the legal or relevant standards (for example,
EN 13241-1, EN 12453, EN 60335-2-95) pertaining to the requirements for the operating forces and therefore the maximum
permissible force limits.
However, the forces to be exerted by the drive can also be reduced (values 1-2) or increased (values 4-9) by the procedure
described below.
Note:
This could be required, for example, if the "Door open" or "Door closed" end stops are not reached with the factory default
setting (value 3). Then the setting for the maximum force - as described below - must be incrementally increased until the
respective end stop is reached.
In addition, the running behaviour of the door may deteriorate (for example, through a depletion of the spring tension) throug-
hout the course of the operating time. For safety reasons, it could then be necessary to adjust the forces, because a manual
actuation which could then be necessary to open or close the door might entail a safety hazard (for example, an uncontrolled
closing of the door) for persons and property.
But
CAUTION:
An increased setting which deviates the factory default setting (value 3) can lead to serious personal inju-
ry and even a mortal danger, as well as severe property damage.
An increased force value which deviates from the factory default setting increases the forces exerted onto the door during
the opening and closing motion. When the factory default setting is changed there is a danger of serious personal injury up
to mortal danger through a possible jamming or crushing of persons or items within in the gate area, as well as the risk of
damage to property, since a force setting which deviates from the factory default setting can possibly lead to an exceeding of
the specified maximum permissible force limits. Therefore, the following shall apply:
Note:
After each force setting change (values 4–9) which deviates from the factory default setting (value 3), the full com-
pliance with the statutory or relevant standards regarding the force limit values must be checked, approved and
documented by a competent person, in order to exclude the indicated dangers for life and limb.
Procedure for changing the factory default setting:
Please note again that the limits of the forces defined by the law maynot be exceeded! Therefore, you should check the com-
pliance with these limit values for each deviation from the factory default setting for the force setting (values 4-9) as descri-
bed in the bold printed note above.
Press the SET button until the LED display shows „3". For a higher force
setting, press the UP button, and the DOWN button for a lower force setting.
Values from 1 to 9 can be set.