Herunterladen Inhalt Inhalt Diese Seite drucken

Injectors Replacement; Adjustment Of Minimum Level - AEG HC411520GB Benutzerinformation

Gaskochfeld
Vorschau ausblenden Andere Handbücher für HC411520GB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If one or more defects are visible, do not repair the pipe, but replace it.
When installation is complete, make sure that the seal of each pipe fitting is correct. Use a
soapy solution, not a flame!

Injectors replacement

1.
Remove the pan supports.
2.
Remove the caps and crowns of the burner.
3.
With a socket spanner 7 remove the injectors and replace them with the ones which
are necessary for the type of gas you use.
4.
Assemble the parts, follow the same procedure backwards.
5.
Replace the rating label (it is near the gas supply pipe) with the one for the new type
of gas supply. You can find this label in the package of the injectors supplied with the
appliance.

Adjustment of minimum level

To adjust the minimum level of the burners:
1.
Light the burner.
2.
Turn the knob on the minimum position.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-pass screw position.
25
Installation

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis