Herunterladen Inhalt Inhalt Diese Seite drucken

Injectors Replacement - AEG HC411520 Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

30
www.aeg.com
Make sure that there is a stop tap
assembles between the gas supply of
house and the appliance.
The settings for this appliance are
located on the rating plate. The present
settings for the type of gas and gas
pressure are on a sticker.
Choose fixed connections or use a
flexible pipe in stainless steel in
compliance with the regulation in force.
If you use flexible metallic pipes, be
careful they do not come in touch with
mobile parts or they are not squeezed.
Also be careful when the hob is put
together with an oven.
This appliance is not connected to an
exhaust gas outlet. It must be connected
in accordance with the installation
conditions that apply. Pay special
attention to correct airflow.
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values. The
adjustable connection is
fixed to the comprehensive
ramp by means of a
threaded nut. R 1/2". Screw
the parts and tighten
everything with teflon tape,
if necessary, to get the right
direction.
A) End of shaft
B) Elbow (if needed)
Flexible nonmetal pipes connection:
If it is possible to easily control the
connection in its full area, you can use a
flexible pipe. Tightly attach the flexible
pipe by clamps.
Liquid gas
Use the rubber pipe holder for liquid
gas. Always engage the gasket. Then
continue with the gas connection.
The flexible pipe is prepared for apply
when:
• it can not get hot more than room
temperature, higher than 30°C;
• it is no longer than 1500 mm;
• it shows no throttles;
• it is not subject to traction or torsion;
• it does not get in touch with cutting
edges or corners;
• it can be easily examined in order to
make sure its condition.
The control of preservation of the flexible
pipe consists in checking that:
• it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length;
• the material is not hardened, but
shows its correct elasticity;
• the fastening clamps are not rusted;
• expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.

8.3 Injectors replacement

1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the
injectors and replace them with the
A
ones which are necessary for the type
of gas you use (see table in
"Technical Information" chapter).
B
WARNING!
When installation is
complete, make sure that
the seal of each pipe fitting
is correct. Use a soapy
solution, not a flame!

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hc411520gb

Inhaltsverzeichnis