Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic TEC60 Bedienungsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für TEC60:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
Servicing the generator
Interval
Inspection/maintenance
➤ Change the oil.
In the first month
➤ Check the air filter (chapter "Servicing the air filter" on page 24).
or after 20 hours.
➤ Check the air filter (chapter "Servicing the air filter" on page 24).
Every 3 months or
after 50 hours.
➤ Change the oil.
Every 6 months or
after 100 hours.
➤ Check the spark plug (chapter "Servicing the spark plugs" on
➤ Check the valves.
Once a year or
every 300 hours
➤ Check the fuel tank (only TEC 60) and fuel filter.
➤ Check the vibration damper.
➤ Check the petrol supply lines (TEC60) and gas supply lines
Every two years
10.2
Preparing maintenance work
!
CAUTION!
Note the following for all maintenance work:
• The generator must not be running.
• All the parts must be cooled down.
➤ Open the generator flap.
➤ Switch the generator to no function with the main switch (fig. 2 1, page 3).
➤ Disconnect the positive terminal of the supply battery.
For maintenance work, you can take the generator out (fig. 5, page 5):
!
WARNING!
The mounting plate with generator is very heavy (> 70 kg) and could fall
out the housing if you take it out too far.
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator from the housing (3).
22