Herunterladen Inhalt Inhalt Diese Seite drucken

Operation - Siemens SIMOTICS GP Kompaktbetriebsanleitung

Vorschau ausblenden Andere Handbücher für SIMOTICS GP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8

Operation

Switching on the machine with anti-condensation heating (optional)
CAUTION
Before switching on, always make sure that the (optional) anti-
condensation heating is switched off.
Machine operation
WARNING
Line supply with non-grounded neutral point
Operating the machine on a line supply system with a non-grounded
neutral point is only permitted over short time intervals that occur rarely,
e.g. the time leading to a fault being eliminated (ground fault of a cable,
EN / IEC 60034-1).
WARNING
Do not remove covers when the motor is running
Rotating or live parts are dangerous. Death, serious injury, or material
damage can result if the required covers are removed.
● De-energize the machine and bring it into a no voltage condition
before removing any covers.
● Ensure that any covers, which are designed to prevent active or
rotating parts from being touched, which are necessary to ensure
correct air guidance and thus effective cooling, or which guarantee
the degree of protection of the machine, remain closed during
operation.
CAUTION
The surfaces of the machines can reach high temperatures, which can
lead to burns if touched.
NOTICE
Minimum load for cylindrical roller bearings
Be sure to comply with the minimum radial load of 30% of the cylindrical roller
bearings in accordance with catalog data.
Standard motors
56100000002001, 02/2013