Settings relative to the auxiliary inputs
If the window contact function is enabled, when the window open condition occurs (contact open) the
thermostat switches to OFF mode (if the control type is in HVAC mode) or activates the Tanti-freeze/Thigh
temperature protection setpoint (if the control type is in setpoint); When the window closed condition is
restored (contact closed), the thermostat resumes the condition it was beforehand.
If the input is enabled for measuring the room temperature with sensor GW10800 or GW1x900, the
temperature measured by the thermostat will not only be determined by the sensor on the device, but will
also be determined by the weighted average between the value measured by the sensor and the value
measured by the external sensor connected to the auxiliary input:
T
= T
measured
auxiliary external sensor
If the input is enabled for measuring the floor temperature, and when the floor temperature exceeds the
limit threshold, the device stops the heating as the temperature of the conduits is too high and could cause
damage (temperature alarm).
USER INSTRUCTIONS
Window contact function for auxiliary input 1
Press the button key
current parameter value is displayed. Enable/disable the window contact
function for the auxiliary input 1 (0 = disabled; 1 = activate) through the
circular touch slider or the push-button
press the button key
(30 seconds) or pressing the push-button
change page without saving it.
Temperature sensor function for auxiliary input 2
Press the button key
current parameter value is displayed. Configure the auxiliary input
function 2 (0 = disabled; 1 = measurement of the room temperature
with sensor GW1x900; 2 = measurement of the room temperature with
sensor GW10800; 3 = measurement of the floor temperature
with sensor GW10800) using the circular touch slider or the push-button
. To confirm the set value, press the button key
seconds; expiry of the time-out (30 seconds) or pressing the push-button
result in exiting the change page without saving it.
x Incidence
auxiliary external sensor
External temperature sensor incidence in measured temperature
calculation
Press the
button key to access value change; after the access,
the current parameter value is displayed. Use the circular touch slider
or the push-button
sensor in the calculation of the temperature measured by the
thermostat (value can be set from 10% to 100%). The parameter is
only displayed if the function of the auxiliary input 2 (P 35) is
"measurement of the room temperature with sensor GW1x900" or
"measurement of the room temperature with sensor GW10800".
to access value change; after the access, the
within thirty seconds; expiry of the time-out
to access value change; after the access, the
+T
x (100%-Incidence
device sensor
to change the incidence (%) of the external
43
. To confirm the set value,
result in exiting the
within thirty
)
auxiliary external sensor
E