Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections - Nice E Plus M Installierungs-Und Gebrauchsanleitungen Und Hinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 67
Quick start guide
Era Plus

1 - Electrical connections

2 - Memorising the FIRST transmitter
01
OFF
Turn OFF
3 - Pairing between the movements of the awning and the control keys
01
5
sec.
Press until ...
03
...
sec.
Press until ...
4 - Programming the two limit switches
01
Release the "arrow" buttons
"0"
Upper limit switch "0"
IS0192A02MM_14-12-2015
Tubular motor for shutters, awnings,
sun screens and similar equipment
- see Chapter 4
1
2
Com.
3
4
L
5
N
6
- see paragraph 5.7
ON
2
sec.
Wait
Turn ON
2
Movements (2)
...
If the awning goes up:
Wait
If the awning goes down:
Release
03
A
Press the button equal to the direction of rotation
Cable Colour
1
White-orange
2
White
3
White-black
4
Brown
5
Blue
6
Yellow-green
02
2
Movements (no. 2)
02
sec.
Release
Press together until ...
3
Movements (3)
Release
04
6
sec.
Press until ...
(the awning goes up)
- ref. paragraph 5.5
02
Press until ...
Note for reading this Guide • In this
Quick Start Guide, the numbering of the
figures is separate and does not cor-
respond to the numbering cited in the
complete manual. • This guide does not
substitute the complete manual.
Connection
Clockwise rotation pushbutton
Counter-clockwise rotation pushbutton / TTBus
Common (for bus wires)
Supply phase
Neutral
Earth
5
3
sec.
Press until ...
Movements (no. 3)
- ref. paragraph 5.8
5
3
Movements (3)
Release together
...
3
Wait
Movements (3)
A
Observe the direction of rotation
B
Release
Release
B
To adjust the
limit switch
"1", repeat the
procedure.
1/1