All local and national laws and European standards must be
met when installing and using the appliance. In Italy, refer to
the UNI 10683/2012 standard, as well as any regional or local
health authority regulations
It is necessary to refer to regulations in force in each country. If
installing in an apartment building, check with the management
company fi rst.
VERIFY COMPATIBILITY WITH OTHER
DEVICES
The stove MUST NOT be installed in the same space as type B
gas heating equipment (e.g. gas boilers, stoves, and equipment
served by an extraction hood) as the stove may cause a vacuum
in the space which may compromise or infl uence how these
units work.
FIRE PREVENTION SAFETY DISTANCES
The stove must be installed in compliance with the following
safety conditions:
- fl ammability items must be kept at a minimum distance of 20
cm from the sides and back of the stove
- fl ammable items must be kept at a minimum distance of 80
cm if placed in front of the stove.
If it is not possible to comply with the above mentioned
distances, technical and construction-related provisions
must be taken to prevent fi re hazards. If connected to wooden
walls or other fl ammable materials, the smoke exhaust pipe
must be appropriately insulated
AIR INTAKE
The room of installation must have a suitable outside air intake
with a through surface area of at least 200 cm
to replenish the burnt oxygen and ensure an adequate combu-
stion air fl ow.
FIRE DAMPERS
The fi re damper should be easily handled and its position must
be distinguished from the outside through the adjustment knob.
The fi re damper must remain fi xed in its position and must not
be able to close automatically.
The fi re dumper must NOT close the fl ue section completely,
but it must guarantee a permanent minimum opening which
should be equal to 3 % of the section itself and in any case
equal to at least 20 cm
2
.
CONVEYING ADJUSTMENT
"Two pipe unions are located on the back of the stoves for hot
air channelling.
Each pipe union can be used to send hot air to an adjacent room
using one KIT 8 per outlet, or both can be used to send air to the
same adjacent room using one KIT 9 (use of a single air grate
for the emission of air into the room)."
"To manage the supply of heating air using the two rear pipe
unions (see Page 14) use:
- Lever control B for the RH union
- Lever control A for the LH union."
N.B. A and B lever controls must only be operated using the
thermal glove supplied as they can heat up considerably.
Various alternatives exist for the distribution of heating air.
INSTALLATION
100% conveyed
50% conveyed LEFT
50% conveyed RIGHT
2
(Ø 16), in order
0% conveyed
- 18
-
Left closed – Right closed
A
B
0%
front grille
Left closed - Right open
A
B
50% right
front panel
Left open - Right closed
A
B
50%
Left front panel
Left open – Right open
A
B
100%
front grille