Herunterladen Inhalt Inhalt Diese Seite drucken

Effect Of Moisture During Transport And Storage; Loading The Combi Heater With Stones; Heater Stones; Loading Stones Into The Heater - Sawotec SCANDIA COMBI NEXT SCA-60NS Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SCANDIA COMBI NEXT SCA-60NS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EffECT of MoISTuRE duRING TRANSpoRT ANd SToRAGE

When performing the final inspection of the electrical installation, a "leakage" may be
detected when measuring the Combi Heater's insulation resistance. The reason for this
is that the insulating material of the heating resistors has absorbed moisture from the air
(during storage and/or transport). After operating the heater for a few times, the moisture
will be removed from the resistors.

LoAdING THE CoMbI HEATER wITH SToNES

The main purpose of the stones in the Combi Heater is to store enough energy to effi-
ciently vaporize the water thrown on top of the stones to maintain correct humidity in the
sauna room. The stones must be removed at least once a year or every 500 hours which-
ever occurs first. All stone crumbles must be removed from the heater then load new
stones as described hereinafter. To verify the required amount of stones, See page 28

HEATER SToNES

The main purpose of the stones in the heater unit is to store enough energy to efficiently
vaporize the water thrown on top of the stones to maintain correct humidity in the sauna
room. The stones must be removed at least once a year or every 500 hours whichever
occurs first. All stone crumbles must be removed from the heater unit and replaced with
new ones as described in the heater manual.
NoTE! Never use the heater without stones as it may cause fire. Use only manufacturer
recommended stones. Using unsuitable stones may lead to heating element damage and
will void the warranty. Never use ceramic stones or other artificial stones of any type!

LoAdING SToNES INTo THE HEATER

It is recommended that all stones should be rinsed to remove any stains or dust that
can cause unpleasant odour during the first few times of using the heater. It is import-
ant that the stones are loaded carefully in a way that they do not block air circulation
through the heater. Larger stones that won't fit between the heating elements must not
be forced in place instead they must be completely removed. Small crumble or stone
pieces smaller than 35mm in diameter must not be loaded into the heater because they
will block the air circulation and will cause overheating and possible heating element
damage.
NoTE! Heating element damage due to overheating caused by wrong kind of stones or
stones which were wrongly loaded into the heater is not covered by the factory warran-
ty.
19
ENGLISH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis