7
Transport and storage
7.1
Transport
Transport the solenoid valve carefully.
G
Avoid knocks and vibration.
G
7.2
Storage
Store the solenoid valve dry in its original
G
packaging.
Store the solenoid valve only with the
G
connections blocked off .
Avoid UV rays and direct sun irradiation.
G
Observe the maximum storage
G
temperature (see chapter 5 "Technical
data").
8
Functional description
The GEMÜ 205 directly controlled 2/2-way
solenoid valve has a plastic valve body.
The fl ow direction is stipulated and indicated
by an arrow on the valve body.
8.1
Valve closed
Valve closed
When the valve is closed the medium flows
into the valve body and presses onto the
piston. The valve remains closed. Observe
the permissible operating pressure (see
chapter 5 "Technical data").
CAUTION
Damage to the solenoid / destruction
of the solenoid!
Danger of burning out of the solenoid if
®
operating pressures are too high!
205
Valve does not open!
The valve cannot be opened
®
electromagnetically if operating
pressures are too high.
8.2
Valve open
When voltage is applied the solenoid in
the valve actuator is activated and lifts the
armature. This opens the valve outlet.
22 / 32
CAUTION
Valve open