Herunterladen Inhalt Inhalt Diese Seite drucken

Test Symbols; Troubleshooting; Appliance Description; Operation - STIEBEL ELTRON MHG 65 E Bedienung Und Installation

Natursteinheizung mhg / mhj / mhs / mhp / mhv / sph serie
Vorschau ausblenden Andere Handbücher für MHG 65 E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATION | INSTALLATION

Troubleshooting

CAUTION Burns
A minimum clearance of 100 mm must be observed on all
sides (500 mm at the front) between the appliance and
all types of objects, such as furniture, curtains, textiles
or other flammable or non-flammable materials.
2.3

Test symbols

See type plate on the appliance.
3.
Troubleshooting
If the natural stone heater does not heat up, check in the fuse
box to see if the associated fuses or RCD have tripped. Remove
the cause.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
4.

Appliance description

The natural stone heater is an electrically heated marble or soap-
stone panel, which is regulated by means of a wall mounted room
temperature controller.
A heating conductor is embedded in the rear of a 30 mm thick
natural stone panel for this purpose, which heats the panel evenly.
Heat stored in the natural stone panel is released in the form of
long wave radiation (comparable with solar rays). Consequently,
occupants and objects alike are heated in the room without any
air turbulence.
Thanks to the use of special rawl plugs for attaching the wall
mounting brackets to the natural stone panel, the mounting points
are invisible from the front. This means that the structure of the
panel is uninterrupted. The wall mounting brackets are convert-
ible, so the natural stone heater can be mounted horizontally or
vertically.
Towel holder
The towel holder available as a special accessory is used for heat-
ing or drying textiles dampened by water (no chemical cleaning
agents).
5.

Operation

The natural stone heater is controlled exclusively via a wall mount-
ed room temperature controller (on finished or unfinished walls).
Observe the operating and installation instructions for the relevant
controller.
6.

Maintenance and care

Clean the natural stone heater with a damp cloth when it has
cooled down.
Do not use any abrasive or corrosive cleaning products.
www.stiebel-eltron.com

INSTALLATION

7.

Safety

Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
- Fit the appliance to a vertical wall that is temperature-resist-
ant to at least 90 °C.
- Maintain the minimum clearances to adjacent object
surfaces.
- Observe the type plate.
- The specified voltage must match the mains voltage.
- Only use a permanent connection to the power supply.
- Never install the appliance directly below a wall socket.
- Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at least
3 mm contact separation. Do not install the appliance with a
fixed power cable.
- When installing the heating appliance in rooms with a
bath and/or shower, observe the safety zone according to
VDE 0100, part 701, in accordance with the details on the ap-
pliance type plate.
The mains junction box must not be installed in safety zone 1
or 2 in this instance.
- Install the appliance in such a way that switching and control
equipment cannot be touched by a person in the bath or
shower.
- Design all materials in accordance with the rated consump-
tion of the appliances.
7.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
MHG, MHJ, MHS, MHP, MHV, SPH |