Connection examples
1. Light without neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1–4 x 100 W filament bulbs
2) Loads, lighting of 1000 W max. (see Technical specifications)
3) IS 360 D TRIO connection terminals
4) Indoor switch
5) Indoor two-circuit single interruption switch, manual operation, automatic operation
6) Indoor two-way switch, automatic operation, manual override
Operation/Maintenance
The motion detector is suit-
Weather conditions may affect
able for switching a light ON
the way the motion detector
or triggering an alarm. The unit
works. Strong gusts of wind,
is not suitable for burglar
snow, rain or hail may cause
alarm systems as it is not
the light to come ON when it
tamperproof in the manner
is not wanted because the
prescribed for such systems.
sensor is unable to distinguish
2. Light with neutral conductor
4. Connection using an indoor two-way
switch for manual override and automatic
operation
Setting I: Automatic operation
Setting II: Manual operation,
light permanently ON
Note: The system cannot be switched OFF,
it is only possible to select operation at setting
I or II.
sudden changes of tempera-
ture from sources of heat.
4
The detector lens
may be
cleaned with a damp cloth if it
gets dirty (do not use cleaning
agents).
- 14 -
- 14 -
Troubleshooting
Malfunction
Cause
n
Without power
Fuse faulty,
not switched ON
n
Short circuit
n
Does not switch ON
Twilight setting in
night-time mode during
daytime operation
n
Bulb faulty
n
Mains power switch OFF
n
Fuse faulty
n
Detection zone not targeted
n
Does not switch OFF
Continuous movement in
the detection zone
n
Light being operated is
located in detection zone
and keeps switching ON as
a result of temperature
change
n
Set to continuous operation
by indoor two-circuit single
interruption switch
n
Keeps switching ON/OFF
Light being operated is
located in detection zone
n
Animals moving in the
detection zone
n
Switches ON when it
Wind is moving trees and
should not
bushes in the detection
zone
n
Cars in the street are being
detected
n
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
Remedy
n
Replace fuse, turn ON
mains switch, check lead
with voltage tester
n
Check connections
n
Adjust setting
n
Replace light bulbs
n
Switch ON
n
Fit new fuse, check con-
nection if necessary
n
Re-adjust
n
Check zone, adjust or fit
shrouds if necessary
n
Change zone, or fit shrouds
n
Set two-circuit single inter-
ruption switch to automatic
operation
n
Change zone or fit shrouds,
increase distance
n
Change zone or fit shrouds
n
Change zone or fit shrouds
n
Change zone or fit shrouds
n
Change detection zone,
change site of installation
- 15 -