Installation Instructions
Installing IS 360 D TRIO
n
Ceiling mounting
detector to trigger a switch-
ing operation, the mains
Caution: Installation means
making connections to the
power must be fed to the
mains power supply. 230 V
load by at least a two-core
cable. To do this, the rub-
means danger to life!
Therefore, switch off the
ber plugs can be pierced
with a screwdriver. Two
power first and use a volt-
age tester to make sure the
pre-punched tabs are pro-
vided on the enclosure trim
wiring is off circuit. Installa-
5
tion of the sensor involves
for surface wiring. These
work on the mains power
are easy to push through.
The mounting plate can be
supply; this means it must
be done properly in accor-
screwed to the ceiling after
feeding the cables through.
dance with VDE 0100.
Please note that the motion
Finally, return the enclosure
5
detector must be protected
trim
by a 10 A circuit breaker.
n
The site of installation
Connecting the mains
power supply lead
should be at least 50 cm
away from a light source,
The main supply lead is a
2 to 3-core cable:
because heat radiated from
it may activate the system.
L =
First remove the enclosure
5
trim
. To do this, lightly
pinch both depressions
N = neutral conductor
while twisting it anti-clock-
wise and pull it down and
PE = any protective
off.
Using a screwdriver, now
undo both fixing screws
If you are in any doubt,
1
identify the conductors
(anti-clockwise) and
remove the mounting plate.
using a voltage tester; then
disconnect from the power
Do not detach internal
wiring from terminal block,
supply again. The terminal
but gently pull out entire
blocks are for the mains
power supply lead. Connect
terminal assembly. Fit the
rubber plug provided into
the live conductor (L) com-
ing from above to the first
the mounting plate. Hold
the mounting plate against
terminal (see arrow) and the
neutral conductor (N) to the
the ceiling and mark where
to drill the holes, paying
second terminal. Connect
attention to any wiring
any green/yellow protective
earth conductor to the last
already existing in the ceil-
ing, drill holes; insert wall
terminal provided.
plugs. For the motion
Blue
Black / brown /
Green / yellow
grey
n
Connecting power supply
cable for load
The load cable (e.g. to the
light) is also a 2 to 3-core
cable. Connect this to
terminals N and L'.
Connect the load's live
conductor (black or brown
cable) to the terminal
marked L'. Connect the
neutral conductor (blue
cable) to the terminal
marked N together with the
neutral conductor of the
mains power supply lead.
and clip into place.
Connect any green/
yellow protective-earth
conductor to the last
terminal.
Important: Getting the
live conductor
cable connections crossed
(usually black,
will produce a short circuit
brown or grey)
in the light or in your fuse
box. In this case, you must
(usually blue)
check the identification of
all cables and re-connect
earth conductor
them. A mains switch for
(green/yellow)
switching the light ON and
OFF can of course be
installed in the mains lead.
- 10 -
Safety warnings
n
n
Disconnect the power supply
During installation, the elec-
before attempting any work
trical wiring you are connect-
on the motion detector and
ing must be dead. Therefore,
securing it in place.
switch off the power first and
check cables with a voltage
tester to make sure they are
no longer live.
Principle
Movement triggers lights,
Whether front door, garage,
alarms and many other
patio or carport, whether
devices. For your convenience
stairwell, storeroom or base-
and safety.
ment, this infrared motion
The IS 360 D TRIO for ceiling
electronically converted into a
mounting is equipped with
signal that switches ON loads
three 120° pyro sensors that
(e.g. a light) connected to it.
detect the invisible heat emit-
Heat is not detected through
ted from moving objects
obstacles, such as walls or
(people, animals etc.). The
panes of glass, and will
heat detected in this way is
therefore not activate the light.
Detection zone approx. 350 m
2
Reach max. 12 m
approx. 5 m
12 m max.
n
Installing the sensor involves
work on the mains power
supply. This means it must
be done properly in accor-
dance with VDE 0100. (
A
VDE 0100,
-ÖVE-EN 1,
-SEV 1000)
detector is quickly installed
and ready for use at any
chosen site.
The three pyro sensors
achieve a coverage angle of
360° with an aperture angle of
180°.
12 m
Note: The most reliable way
of detecting movement is to
install the light with the sensor
aimed across the direction in
which a person would walk
and by ensuring that no
obstacles (such as trees,
walls etc.) obstruct the line
of sensor vision.
- 11 -