• Before installing the scale, check that the alignment of the installation surface (or installation brackets) is
within the standards.
• Use a scale installation bracket, where applicable, having a length covering the entire scale length. Even
when using divided brackets, be sure to always check that the alignment of the installation brackets is
within the standards.
• The rear surface of the scale unit is used as the installation guide.
• Loosely turn the mounting screws first. Determine the alignment and then tighten the screws to fasten the
scale. (See Fig. 5.)
Fig. 5
Scale :
4
(E)
×
M6
35
(9 N
m)
Bring into contact
×
Slider :
M4
20
(2.7 N
m)
SR84 / SR85, CH33