Herunterladen Inhalt Inhalt Diese Seite drucken

FAAC 412 Compact Bedienungsanleitung Seite 16

Vorschau ausblenden Andere Handbücher für 412 Compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
ENGLISH
The FAAC 412 COMPACT AUTOMATION SYSTEM for swing gates
comprises two electromechanical operators which drive the
gate leaves by means of a worm screw.
The system locks mechanically; therefore no electric lock is
required.
The 410 MPS control unit supplied with the automation kit
enables programming and control of system operation.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
Motor Unit
Power cable
Worm screw
Front bracket
12
10
Power supply+Earth terminal
block
Flashing light and motor terminal
block
Low voltage terminal block
Decoder card connector
Torque adjusting trimmer
Pause time adjusting trimmer
Opening/Closing time
412 COMPACT AUTOMATION SYSTEM
Rear bracket
Cable cover
Cover
4
11
8
7
9
2
1
adjusting trimmer
Closing leaf delay time
adjusting trimmer
Programming microswitches
Fuse F1 (motor) 5x20 5 A /250
V rapid
Fuse F2 (accessories) 5x20 800
mA /250 V delayed
Fuse F4 (transformer) 5x20 250
mA /250 V delayed
Table 1: 412 operator technical specifications
Power supply
Absorbed power
Current drawn
Electric motor
Motor winding thermal cutout
Capacitor
Max. thrust/traction force
Rod stroke
Rod speed
Temperature range
Operator weight
Housing protection
Duty cycle
Maximum leaf length
Table 2: 410 MPS control unit technical specifications
Power supply
Absorbed power
Max. motor load
Max. accessories load
Temperature range
Fuses
Fig. 1
Operation logics
Opening/closing time
Pause time
Closing leaf delay time
Opening leaf delay time
Thrust force
Terminal block inputs
Terminal block outputs
6
Quick connector
5
Microswitch programmable
functions
Housing dimensions
Housing protection
2. STANDARD INSTALLATION LAYOUT
3
Fig. 2
Operators (require 2 junction boxes)
Photocells
410 MPS control unit
T10 pushbutton
Receiver
Flashing light
Notes:1) Use suitable rigid/flexible pipes for laying power cables.
2) Always keep low voltage accessory cables separate
from 230V~ power cables. To avoid interference, use
separate sheaths.
13
ENGLISH
230 V~ ( +6% -10%) - 50 Hz
350 W
1.5 A
4 poles - 1400 rpm
140 °C
8 µF / 400V
320 daN
290 mm
1.6 cm/s
-20 °C +55 °C
6.5 Kg
IP 53
18 cycles/hour
1.80 m
230 V~ ( +6% -10%) - 50 Hz
10 W
800 W
0,25 A
-20 °C +55 °C
3 (see fig. 2)
Automatic/Semi-automatic/Safety/
Step-by-step semi-automatic
Adjustable by trimmer (from 0-62 seconds)
Adjustable by trimmer (from 0-240 seconds)
Adjustable by trimmer (from 0-28 seconds)
2.5 seconds (fixed)
Adjustable by trimmer
Open/Stop/Opening safeties/
Closing safeties/mains power + earth
Flashing light - motors - 24 Vdc
accessories power supply
Decoding cards - RP 433 SL/DS
Operating logics -
Closing safeties logics
265 x 204 x 85
IP 55
Fig. 3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis