CAUTION:
• Set the snug point detection level from
"L1." Setting the snug point detection level
from "L" may result in cracking or defor-
mation of the target material.
• If the tool stops before the snug point at
snug point detection level "L1," set the
snug point detection level to "L."
• Changing the snug point detection level
from "L1" to "L" may increase the torque.
Set the number of torque stages again
after making this change.
• The setting will not be changed until
you press the OK button.
• After changing the setting, be sure to check
the new setting value. (See page 13.)
IMPORTANT INFORMATION:
• You can set the snug point detection
level and retightening prevention time at
the same time by changing the retight-
ening prevention time (see page 1)
before pressing the OK button and then
pressing the OK button.
• Pressing the torque setting mode but-
ton toggles the display between the
snug point detection level setting value
and the number of torque stages set-
ting value.
• The tool ships with the snug point
detection level set to "L1."
• When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from "L1" to "L."
Number of torque stages
Model
EYFLA4
EYFLA5
Snug point detection level guidelines
Display
L1
(Use for work characterized by low loads
before the snug point is reached.)
L
(Use for work characterized by high
loads before the snug point is reached.)
setting
1 to 8
1 to 3
Snug point detection level
Low
High
Tightening Torque Chart (for Reference
Use)
The values illustrated on this chart were mea-
sured under the conditions described below
and are provided for reference purposes.
Actual tightening torque varies with ambient
conditions (the particular bolt being tightened,
hardware being used, method of holding the
bolt in place, etc.).
Measurement conditions
• Temperature: Room temperature (0°C/68°F)
Using the Interval Set
• The interval set operates to prevent the tool
from operating after it automatically stops as
a result of the torque control function, even if
the switch is engaged.
1. Set the tool to configuration mode.
(See page 10.)
. Press the interval set button.
• The control panel will begin flashing.
Display: The number 0 flashes on and off.
Battery indication lamp: The middle bar
of the battery flashes on and off.
Display
Applications (reference)
• Tightening bolts in materials that are
easily cracked or deformed, etc.
• Tightening bolts in materials with mis-
aligned holes, etc.
• Tightening self-tapping screws, etc.
- 1 -
EYFMA1(M14)
EYFMA1(M12)
EYFMA1(M10)
EYFLA6(M8)
EYFLA5(M6)
EYFLA4(M6)
Battery indication lamp
EYFLA6(M10)
EYFLA5(M8)
EYFLA4(M8)