Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Mains overvoltage or undervoltage
Check the mains voltage
Phase failure
Check the mains lead
Temperature sensor defective
Check temperature sensor and replace if necessary
Electrolyte circulation pump defective
Check electrolyte circulation pump and replace if necessary
Battery undervoltage
Check parameter settings and battery voltage
Battery overvoltage
Check parameter settings and battery voltage
Battery overtemperature
Check parameter settings and check battery for defects
Charging time exceed in I1 phase
Check parameter settings and check battery for defects
Charging time exceed in U1 phase
Check parameter settings and check battery for defects
Overvoltage on the battery (only when recharging)
Check parameter settings and battery voltage
Error at the end of the U1 phase
Check battery for defects