Herunterladen Inhalt Inhalt Diese Seite drucken

Operating The Engine (Honda); Starting The Engine - Ammann AVP 2620 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Operation

3.5 Operating the engine (HONDA)

1
II
2
Close
3
4

3.5.1 Starting the engine

To prevent engine damage through oil deficiency, the
engine is provided with a low oil warning system. If the
oil level is too low, the engine switches off
Important
automatically (the engine switch remains in the ON
position).
Move fuel tap (3) to «ON».
Move choke lever (2) to «CLOSE».
Adjust engine speed control lever (1) to full load.
Move engine switch (5) to «ON».
Pull starter handle (4) slightly until a resistance is felt, then pull
out sharply.
Allow engine to warm up for 1 ... 2 minutes.
As the engine warms up, gradually move the choke lever (2)
to «OPEN» position
Do not allow starter handle to rebound against the
engine. Guide starter cable back by hand to the
reset position.
Attention
Do not operate choke lever if engine is warm or at
high outside temperature.
3.5.2 Switching off the engine (HONDA)
Adjust engine speed control lever (1) to idle position.
Turn motor stop button (4) on to position «OFF».
Turn fuel tap (3) to «OFF».
In emergency situation turn the engine switch on to
«OFF» to stop the motor immediately.
Important
I
ON
ON
5
31