Valve soiled or clogged
-
Pressure gauge does not show full pressure
-
The high pressure hose vibrates
-
Water exits intermittently
-
Valves can become clogged if you have not used the
device for an extended period.
1.
If a valve is clogged,
2.
the pressure gauge will show little or no pressure!
3.
Otherwise the high pressure cleaner will vibrate!
4. Use a ring spanner to open the valve...
5.
... and remove the valve screw, the valve and the
rubber ring,
6.
straighten a paper clip...
7.
... and use it to remove the dirt from the valve
- the inside valve must be closed!
8. Push the rubber seal back in tight!
9.
Re-tighten the valve screw
10. ... and repeat this for all 6 valves!
11.
That is how quick the fault is eliminated!
Valve housing