Install the 12 V control box at a place protected from sun radiation (max. 40 °C).
Variant 1 (E):
− Push the ground stake (5) fully into the ground at the desired position.
− Slide the 12 V control box (3) onto the ground stake (5).
Variant 2 (F):
− Screw the 12 V control box (3) to the ground using 4 screws (13) (not included in our scope of delivery) through
the fastening slots (14) in the housing of the 12 V control box (3).
Installation of the transformer (G):
Install the transformer (2) close to the 12 V control box (3).
Note: Ensure that the cables are routed strain relieved!

Electrical installation

Connect the unit to the 12 V control box (G, H):
− Plug the pump plugs (18) as well as the LED light nozzle plugs (20) into the respective sockets for the pump (19)
and the LED light nozzles (21) of the 12 V control box (3). Note the order of the plugs (plugs are marked).
− Insert the connection cable (17) of the transformer in the rear socket (15) of the 12 V control box (3), then screw-
tighten the cable with the union nut (16).
− Fit the protection sleeve (4) over the 12 V control box (3).
Start-up
Switching on the unit (I): Plug the power plug (22) of the transformer into the socket.
− The Water Trio / Water Quintet starts with program 1 (see chapter Operation).
Switching off the unit (I): Disconnect the power plug (22) of the transformer.

Operation

14
the manual transmitter (A, 7) can be used to select 9 programmed water feature patterns.
Program 1 appears automatically when starting up and with each new start of the unit.
P0
Unit off, stand-by mode
P1
All fountains active, fixed height up to max. 30 cm
Light on for all fountains
P2
All fountains active, fixed height up to max. 70 cm
Light on for all fountains
P3
All fountains active, dynamic fountain height, max. 70 cm high
Light on for all fountains
P4
One fountain each alternatingly active in intervals, max. 70 cm high
Light switched on for each active fountain
P5
All fountains active, fixed height up to max. 110 cm
Light on for all fountains
P6
All fountains active, dynamic fountain height, max. 110 cm high
Light on for all fountains
P7
One fountain each alternatingly active in intervals, max. 140 cm high
Light switched on for each active fountain
P8
All fountains active, dynamic fountain height, max. 140 cm high
Light on for all fountains
P9
Several fountains alternatingly active, max. 140 cm high
Light switched on for the respective active fountains
Select next program: Button 1
Select previous program: Button 2
Note:
− If the unit is switched by means of a timer, always program 1 is started.
− Fountain heights can be varied.