3.12.4

Canceling scan mode

If the OSCAR interface is open, select a target device.
-or-
If the OSCAR interface is not open, move the mouse or press any key on the
keyboard to stop scanning at the currently selected target device.
3.13

Running switching system diagnostic tests

You can validate the integrity of the switching system through the Run Diagnostics
command. This command checks the appliance functional sub-systems (memory,
communications, earlier appliance model control, and the video channels) for each
system controller.
Figure 25: Diagnostics window
Click Commands - Run Diagnostics. A warning message indicates that all users
(remote and local) will be disconnected.
Click OK to begin diagnostics. All users are disconnected and the Diagnostics
window opens.
The top section of the window opens the hardware tests. The bottom portion
divides the tested KVM-IAs into three categories: On-line, Offline, or Suspect. KVM-
IAs might be listed as offline while being upgraded.
As each test finishes, a pass (green circle) or fail (red x) symbol becomes visible to
the left of the item. The test is complete when the last test symbol is visible.
590-591-609D
Canceling scan mode
39