Reliable earthing: Maintain reliable earthing of rack-mounted equipment. Pay
particular attention to supply connections other than direct connections to the
branch circuit (for example, use of power strips).
2.4.2
Installing a KVM appliance in the rack
mounting space
Remove the screws on each side of the KVM s3-1621 appliance.
Line up the holes in the long side of each mounting bracket.
With a Phillips screwdriver, fasten the mounting brackets to the KVM s3-1621
appliance, using two 8/32-inch x 1/2-inch pan-head screws on each side.
Attach four cage nuts or clip nuts to the rack mounting flange of the rack so that the
nut is positioned on the inside of the rack.
Mount the KVM s3-1621 appliance assembly to the rack by matching the holes in
the short side of each mounting bracket to a set of matching holes on the rack.
Insert the combination Phillips screws through the slots in the mounting bracket and
the holes in the mounting rail, then into the cage nuts or clip nuts.
Figure 5: KVM s3-1621 appliance horizontal installation
2.5

Connecting the KVM appliance hardware

Turn off the target devices that are part of the switching system. Connect one end of
the power cord to the rear of the KVM s3-1621 appliance, and connect the other
end to an ac power source.
Connect a VGA monitor and either PS/2 or USB keyboard and mouse cables into
the labeled KVM s3-1621 appliance ports. You must install both a keyboard and
590-591-609D

Installing a KVM appliance in the rack mounting space

11