Functional description

The wall and ceiling sander is especially designed for efficient sanding of wall and ceiling surfaces in new and renovated
buildings. Moreover, it is designed for use with a vacuum cleaner for minimum dust generation and optimum sanding
results. The pivoting sanding head enables excellent results with minimum time and effort.

Electrical connection

The mains voltage must be 230 V/50 Hz. The sander must not be used if the power cord is damaged. A damaged power
cord must be replaced immediately by an authorised customer service centre. Do not try to repair the damaged power
cord yourself. Use of damaged power cords can lead to electric shock.

Unpacking

Carefully take out the tool and all loose items from the shipping carton. Retain all packing materials after you have in-
spected the tool.
Do not operate the sander until you have read the entire instruction manual.
Attaching the sanding media
(1) Unplug the device.
(2) Remove the worn sanding disc from the hook-and-loop sanding pad, which remains at its position.
(3) Carefully centre-align the new sanding disc and press it down. It will be held securely by the hook-and-loop sanding
pad.
Replacing the hook-and-loop sanding pad
The hook-and-loop sanding pad must be absolutely even in order to achieve good sanding results. Deformed or damaged
pads will do an uneven sanding job. Always replace damaged pads. The pad has a hook-and-loop film on both sides; to
replace the hook-and-loop film, remove the entire pad and replace it with a new hook-and-loop sanding pad.
Replacing the brush collar at the edge of the sanding head
The brush collar at the edge of the sanding pad serves two purposes: it keeps the sanding disc properly aligned with the
work surface, thereby preventing the formation of grooves, and it supports the dust suction with the vacuum cleaner.
These brush bristles will wear with continued use. When the brush collar is worn the entire sanding plate cover must be
replaced to ensure effective dust suction and stabilisation of the sanding pad.