7. Technical data

Phoenix Inverter Smart
Parallel and 3-phase operation
Input voltage range (1)
Output
Cont. output power at 25ºC
Cont. output power at 25ºC
Cont. output power at 40ºC
Cont. output power at 65ºC
Peak power
Dynamic (load dependent) DC low shut
down (fully configurable)
Max. efficiency 12/ 24 /48 V
Zero load power 12 / 24 / 48 V
Zero load power in ECO mode
Programmable relay (2)
Stop & start power ECO-mode
Protection (3)
Bluetooth wireless communication
VE.Direct communication port
Remote on-off
Common Characteristics
Common Characteristics
Battery-connection
230 V AC-connection
Weight
Dimensions (hxwhd)
Safety
Emission Immunity
Automotive Directive
1) Non-linear load, crest factor 3:1
2) Programmable relay that can a.o. be set for general
alarm, DC under voltage or genset
AC rating: 230 V / 4 A
DC rating: 4 A up to 35 VDC, 1A up to 60VDC
12 Volt
24 Volt
48 Volt
INVERTER
Output voltage: 230VAC ±2%
(2)
https://www.victronenergy.com/live/ve.direct:phoenix-inverters-
GENERAL
Operating temperature range: -40 to +65ºC (fan assisted
ENCLOSURE
Material & Colour: stainless steel (blue RAL 5012; and black
485x219x125mm
STANDARDS
EN 55014-1 / EN 55014-2/ IEC 61000-6-1 / IEC 61000-6-2 /
3) Protection key:
start/stop function.
12/1600
24/1600
48/1600
No
9,3 – 17V
18,6 – 34V
1600 W
1300W
1200W
800W
3000VA
Dynamic cut-off, see
dynamic-cutoff
92/94/94 %
8/9/11 W
0,6/1,3/2,1 W
Yes
adjustable
a - g
For remote monitoring and system integration
For remote monitoring and system integration
Yes
cooling)
Humidity (non-condensing): max 95%
RAL 9017)
Protection category: IP 21
M8 bolts
Screw terminals
12kg
EN 60335-1
IEC 61000-6-3
ECE R10-5
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high
12/2000
24/2000
48/2000
37,2 – 68V
50 Hz or 60Hz ± 0,1% (1)
2000 W
1600W
1450W
1000W
4000W
92/94/94 %
8/9/11 W
0,6/1,3/2,1 W
2+2 M8 bolts
13kg
485x219x125mm
11