5. CONFIGURATION
Settings may only be changed by a qualified engineer.
Carefully read the instructions before changes are made.
Batteries should be placed in a dry and well-ventilated area during charging.
5.1 Standard settings: ready for use
On delivery, the Phoenix inverter is set to standard factory values. In general, these
settings are suitable for stand-alone operation.
Standard factory settings
Inverter frequency
Inverter voltage
Search mode
Programmable relay
Dynamic cut-off
5.2 Explanation of settings
Inverter frequency
Output frequency
Adjustability: 50Hz; 60Hz
Inverter voltage
Adjustability: 210 – 245V
ECO Mode
If ECO mode is 'on', the power consumption in no-load operation is decreased by approx.
80...90%. In this mode the Phoenix Inverter Smart, when operating in inverter mode, is
switched off in case of no load or very low load, and switches on every two and a half seconds
for a short period (adjustable). If the output current exceeds a set level, the inverter will
continue to operate. If not, the inverter will shut down again.
The ECO Mode can be set with the push button on the front of the inverter.
The ECO Mode "shut down" and "remain on" load levels can be set with Victron Connect .
The factory settings are:
Shut down: 50 Watt (linear load).
Turn on: 100 Watt (linear load).
Programmable relay
By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in
the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too
high, battery voltage almost too low).
50 Hz
230 VAC
off
alarm function
off
9