EngyCal® RH33
5
Operation
5.1
General notes for operation
The BTU meter can be configured using keys or using the "FieldCare" operating software.
The operating software, including the interface cable, is available as an order option, i.e. it is not
part of the basic scope of delivery.
The configuration is locked if the device is locked by the custody transfer switch, user code or
digital input. For devices locked by custody switch, custody transfer-related parameters can be
changed only up to three times. Afterwards, no more access to these parameters is possible. (For
details, refer to the section on "Access protection" in the Operating Instructions on CD-ROM)
5.2
Display and operating elements
Fig. 19: Display and operating elements of the BTU meter
1
Green LED, "Operation"
2
Red LED, "Fault indicator"
3
USB connection for configuration
4
Operating keys: -, +, E
5
160x80 DOT matrix display
!
Note!
Green LED for voltage, red LED for alarm/error. Green LED is always illuminated as soon as
power is supplied to the device.
Slow flashing of the red LED (approx. 0.5 Hz): the device has been put into bootloader mode.
Fast flashing of the red LED (approx. 2 Hz): in normal operation: maintenance required. During
firmware update: data transmission active.
Red LED illuminated constantly: device error.
Endress+Hauser
Operation
a0013444
27