Problem
Water remains cold, LED remains off
Water remains cold, the pilot lamp "Power"
lights
Water remains cold, the pilot lamp "Pressure"
lights
Water flows lower as expected
The hot water is not hot enough
Temperature and pressure vary

16. Troubleshooting

Possible Cause
Circuit breaker tripped
Heating element or electronics faulty
Safety thermal cut-out tripped
Flow rate too low
Depends on the heater
Outlet fitting dirty or calcified
Filter dirty or calcified
Tap not suitable
Electronic board
Flow rate is too high (winter?)
Heating element defect
Cold water is being added
If you experience a malfunction, please try to rectify the fault your self first with the help
of this table. If a fault in your appliance cannot be rectified with the aid of this table,
please contact CLAGE who will either assist you directly or put you in touch with a
customer service contract partner in your area. Always specify the appliance model and
serial number, please!
Repairs may only be carried out by authorized professionals.
CLAGE GmbH
Customer Service
Pirolweg 1 – 5
21337 Lüneburg
Germany
Phone:
+49 (0) 4131 · 89 01- 38
Fax:
+49 (0) 4131 · 89 01- 41
E-mail:
service @clage.de
Internet: www.clage.de
14
Solution
Have the fault rectified and reset
Reset fuse, contact customer service
Reset. In case of repeated trips contact
customer service
Increase flow pressure
Check technical specifications
Clean tap fitting or shower head
Clean or renew the filter
Use CLAGE shower head or aerator
Reset fuse
Reduce the water flow slightly
Contact customer service
Only hot water can bedelivered to within